You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 5 No. 6, Nov-Dec 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Facial Plastic Surgery
 •Reconstructive Facial Surgery
 •Alert me on articles by topic

Comparison of Absorbable With Nonabsorbable Sutures in Closure of Facial Skin Wounds

G. Joseph Parell, MD; Gary D. Becker, MD

Arch Facial Plast Surg. 2003;5:488-490.

ABSTRACT

Background  There is long-standing disagreement among facial plastic surgeons as to the ideal suture material for closing skin wounds of the face. Many surgeons believe that nonabsorbable suture material is preferable, as it is easier to tie, is unlikely to break prematurely, and elicits a minimal inflammatory response. Others feel that these issues are of minor importance and prefer absorbable sutures because they do not have to be removed, thus saving the surgeon time and decreasing patient anxiety and discomfort.

Patients and Methods  Facial skin cancers were removed from 41 patients. The length of closure ranged from 3.5 to 12.0 cm. All wounds were closed with rotational advancement flaps. Deep tissues were closed with 4-0 poliglecaprone 25 (Monocryl; Ethicon Inc, Somerville, NJ). One half of each wound was randomly closed with 5-0 coated polypropylene (Prolene; Ethicon Inc), while the other half was closed with 5-0 coated irradiated polyglactin 910 (Vicryl Rapide; Ethicon Inc). No wound infections or premature rupture of sutures occurred. All patients were followed up for 6 months after surgery. The photographs of the results were reviewed, and no difference was noted in scar formation.

Conclusions  In adults with clean wounds of the face or neck, there is no difference in long-term cosmetic results of repairs with permanent or absorbable suture material. We prefer absorbable sutures, as they do not have to be removed, saving the surgeon time and lessening patient anxiety and discomfort.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

WOUND closure using suture material is an ancient art that was alluded to in Egyptian scrolls circa 3500 BC. Animal hair, vegetable fibers, silk, leather, and gut have been used with varying degrees of success.1 Not surprisingly, there is no consensus among facial plastic surgeons as to the best material for closing skin wounds of the head and neck. Monofilament sutures glide easily through tissue and cause minimal reaction. Some monofilament sutures, such as nylon, are springy, making them difficult to tie, with a tendency to unravel. Also, if they are tied under tension, they may cut tissue. Braided sutures have less memory, making them easier to tie. However, bacteria can be wicked into the interstices, promoting infection. In addition, these sutures expand as they absorb fluid, sometimes causing knots to untie. Many surgeons believe that nonabsorbable suture material is preferable, because it is easier to tie, it is unlikely to break prematurely, and it elicits a minimal inflammatory response. Others prefer absorbable sutures because they do not have to be removed, saving time and decreasing patient anxiety and discomfort. LaBagnara2 has written a good review of absorbable sutures. The ideal suture would be a flexible monofilament with adequate tensile strength that holds knots well and absorbs in 7 to 10 days. No such suture material is available today.

Both of us have large facial reconstructive surgical practices. The first author (G.J.P.) reconstructs approximately 400 defects after skin cancer removal each year. Before this study, the skin was closed exclusively with nonabsorbable polypropylene (Prolene; Ethicon Inc, Somerville, NJ). Gut sutures were avoided as they caused a significant inflammatory reaction, with unreliable absorption. Synthetic absorbable sutures remained too long, promoting infection or unraveling. The advent of coated irradiated polyglactin 910 (Vicryl Rapide; Ethicon Inc) prompted this study. This suture material is derived from ordinary polyglactin 910 (Vicryl; Ethicon Inc), which undergoes ionization to speed its absorption, without changing its mechanical properties. It dissolves in 7 to 10 days3 and holds well if 4 square knots are tied.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

The first author resected 44 skin cancers from the head and neck area in 41 adult patients. The length of the closure ranged from 3.5 to 12.0 cm, with an average length of 7.5 cm. Four wounds were on the neck and 37 were on the face. The wounds were closed with standard rotational advancement flaps. The subcutaneous tissue was closed with an absorbable suture (poliglecaprone 25) (Monocryl; Ethicon Inc). Simple interrupted sutures were used to close one half of the wound with 5-0 Vicryl Rapide and the other half with 5.0 Prolene. The Prolene sutures were removed 1 week after surgery, and the Vicryl Rapide sutures were allowed to dissolve. Patients were followed up at regular intervals, and the wounds were photographed at 3 and 6 months with a commercially available 35-mm camera (Olympus), 105-mm lens, flash attachment, and color film (Kodachrome ASA 64). The second author (G.D.B.) reviewed the photographs. Comparison of inflammatory response and stitch scarring was made between the Prolene- and the Vicryl Rapide–sutured wounds. Inflammatory response was graded 0 through 3 (0, none; 1, hyperemia; 2, hyperemia with swelling; and 3, purulence). Scarring was also graded 0 through 3 (0, no visible scars; 1, barely visible stitch scars; 2, obvious stitch scars; and 3, hypertrophied stitch scars). One gram of ceftriaxone sodium (Rocephin) was intravenously administered to all patients at the time of wound repair.


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

Specific wound sites are noted in Table 1. In the present series, the only complications were mild scarring (grade 1) and inflammation (grade 2). Railroad tracking was only visualized when the skin was stretched. Inflammation was minor, did not require treatment with antibiotics, and was generalized rather than localized around individual sutures. Railroad tracking occurred in 3 areas closed with Prolene and in 2 areas closed with Vicryl Rapide. In 1 of these wounds, tracking occurred with both Prolene and Vicryl Rapide. All tracking occurred in the transitional area between the mandible and the neck. Overall, no significant difference was noted between the areas closed with Prolene and those closed with Vicryl Rapide. Wound infection did not occur.


View this table:
[in this window]
[in a new window]
Wound Locations and Results



COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

Comparison of our results with those of other studies would not be accurate because of differences in methodology. Other studies comparing Vicryl Rapide with nonabsorbable sutures have seldom included the head and neck.4-6 Also, the wounds in other studies were lacerations and were closed primarily by either residents or experienced surgeons. Our patients' wounds required rotational advancement flap closure with inherent increased wound tension. The first author performed all closures. In addition, each patient acted as his or her own control, as both suture materials were used on the same wound.

It is most important to minimize wound tension when repairing skin wounds. This is accomplished by following the relaxed skin tension lines and placing all tension on the subcutaneous closure. Skin margins are minimally undermined (approximately 3 mm). Wider undermining increases ischemia, which slows healing and increases swelling and risk of infection.7 Horizontal mattress sutures using 4-0 Monocryl were passed through the subcutaneous tissue immediately deep to the separated margin of the skin and subcutaneous tissue. The sutures were tightened until the skin edges were slightly averted. Monocryl is ideally suited for use in the head and neck because it maintains strength for about 14 days and is well absorbed in about 30 days. It rarely extrudes or forms a suture abscess. Other factors affecting scarring include elasticity of the skin, postoperative wound edema, infection, local muscle tension, and location of the wound over a bony prominence, all of which are associated with increased wound tension.

Children and young adults have very high skin elasticity. Because of this, pediatric wounds have a much greater tendency to stretch into a wider scar over time. Since all our patients were adults, high skin elasticity was not a factor. Nevertheless, it is worth noting that children's wounds must be closed with extra care to avoid excess tension. Subcuticular closure or tissue glue (Dermabond) may be preferable in selected cases.8 Generally, we do not recommend glue, as it does not lend itself well to precise skin apposition.

Skin sutures are tied without tension to allow for postoperative edema; otherwise, railroad track suture scars may result. Railroad tracking occurred in a mild form (grade 1) in 5 patients and was located at the transitional area from the cheek to the neck. Location of a wound where there is significant movement or over a bony prominence increases wound tension, resulting in widening of the scar and/or railroad tracking. Increased wound tension occurred most commonly over the mandible, where there is both movement and a bony prominence. An extra-strong subcutaneous closure is helpful in preventing widening and railroad tracking of the scars. Also, there is excess tension at the face-neck junction, where the relaxed skin tension lines are 90° opposed. We have not seen epithelial cyst or sinus formation with Vicryl Rapide or Prolene. Contrary to the observations of Webster et al,9 we have seen such formation occur with fast-absorbing catgut, especially when it is used on the eyelid.


CONCLUSIONS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

In adults with clean skin wounds of the face or neck, there is no difference in long-term cosmetic results of repairs between nonabsorbable and synthetic absorbable sutures. The use of absorbable material may be preferable because the sutures do not have to be removed, which saves the surgeon time and may lessen patient anxiety and discomfort.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

Corresponding author and reprints: G. Joseph Parell, MD, 330 W 23rd St, Panama City, FL 32405.

Accepted for publication March 27, 2003.

From the Departments of Otolaryngology–Head and Neck Surgery, University of Florida Medical Center, Gainesville, Fla (Dr Parell), and Kaiser Permanente Medical Center, Panorama City, Calif (Dr Becker).


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Conclusions
 •Author information
 •References

1. Margota R. The Story of Medicine. New York, NY: Golden Press; 1968.
2. LaBagnara J Jr. A review of absorbable suture materials in head & neck surgery and introduction of Monocryl: a new absorbable suture. Ear Nose Throat J. 1995;74:409-415. PUBMED
3. Vicryl Rapide. Somerville, NJ: Ethicon Inc; 1998. [package insert]
4. Emslander H. A double-blind, prospective outcomes evaluation of rapidly absorbing synthetic suture as compared to non absorbable suture in primary skin closure. J Emerg Med. 1998;16:36S.
5. Duprez K, Bilweis J, Duprez A, Merle M. Experimental and clinical study of fast absorption cutaneous suture material. Ann Chir Main. 1988;7:91-96. FULL TEXT | PUBMED
6. Engels M. Intracutaneous skin sutures using Vicryl Rapide in the infant and young child [product information]. Somerville, NJ: Ethicon Inc; 2000.
7. Borges A. Elective Incisions and Scar Revision. New York, NY: Little Brown & Co; 1973:42.
8. Simon HK, McLario DJ, Bruns TB, Zempsky WT, Wood RI, Sullivan KM. Long-term appearance of lacerations repaired using tissue adhesive. Pediatrics. 1997;99:193-195. FREE FULL TEXT
9. Webster RC, McCollough EG, Giandello PR, Smith RC. Skin wound approximation with a new suture material. Arch Otolaryngol. 1985;111:517-519. FREE FULL TEXT


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

The Effect of a Hydrogen Peroxide Wound Care Regimen on Tensile Strength of Suture
Athre et al.
Arch Facial Plast Surg 2007;9:281-284.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | SUBMIT | SUBSCRIBE | HELP