You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 10 No. 2, Mar-Apr 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Research Letters
 This Article
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on Web of Science (1)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Aging/ Geriatrics
 •Otolaryngology/ Head & Neck Surgery
 •Airway Obstruction
 •Facial Plastic Surgery
 •Biomaterials and Implants
 •Nasal Surgery
 •Alert me on articles by topic

A Follow-up Study of the Monarch Adjustable Implant for Correction of Nasal Valve Dysfunction

Charles Gerard Hurbis, MD

Arch Facial Plast Surg. 2008;10(2):142-143.

Dysfunction of the nasal valve is becoming an increasingly common cause of nasal airway obstruction as the general population ages. Senile nasal changes are becoming the most common reason for valve dysfunction.1 Because the nasal valve represents the smallest segment of the respiratory tract in cross-sectional area, even small changes in size or wall support can have a profound affect on nasal airflow.2 Consistent correction of the nasal valve has proved challenging for surgeons, where choice and proper execution of the appropriate surgical technique are critical for success. Still, consistent results can be evasive even for the experienced surgeon.

The Monarch implant (Hanson Medical, Kingston, Washington) is designed to function like the cartilaginous butterfly graft or effectively as an adjustable implanted Breathe-Right dilator (CNS Inc, Minneapolis, Minnesota). It corrects valve obstruction at both the internal and external levels for both dynamic and static dysfunction.3 The Monarch implant is a bimaterial device with an expanded polytetrafluoroethylene vs reinforced silicone outer casing surrounding a malleable titanium core. The malleability of the device allows the surgeon to fine-tune the airway to obtain an optimal valve area with aesthetic balance. Adjustments can be made during surgery or after surgery in the physician's office.

Methods

A total of 16 patients underwent implantation by techniques previously described.3 Two patients had concurrent septoplasty, whereas 5 had turbinate reductions. Nine patients were followed for a 6-month period. Valve collapse was diagnosed by way of physical examination, acoustic rhinomanometry (Rhinometrics; Interacoustics AS, Assens, Denmark), inspiratory nasal base view photographs, and a subjective questionnaire. The patients' mean age was 66 years. Data were obtained before surgery and at 1-month intervals after surgery.


Results

At 1 month after surgery, questionnaire data revealed a great improvement in daytime and nighttime nasal airway ratings. The snoring rating dropped substantially, with a slight drop in apnea, a slight increase in olfactory function, and a decreased propensity for daytime mouth breathing. Inspiratory base view photographs showed a pronounced increase in the dynamic area of the external valve, whereas rhinomanometry revealed a substantially improved static internal nasal valve area (Table).


View this table:
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Table. Patient Questionnaire, Static Acoustic Rhinomanometry, and Dynamic Photographic Dataa


At 6 months after surgery, questionnaire ratings demonstrated slight improvements over the 1-month scores except for a slight return in mouth breathing. Rhinomanometry data revealed further improvement in the internal nasal valve area, whereas base view photographs revealed a decrease in external nasal valve stability (Table, Figure).


Figure 1
View larger version (63K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Figure. A patient with nasal valve dysfunction. A, Before surgery; B, after surgery.



Comment

Questionnaire results revealed stability at 6 months compared with the 1-month data. Daytime nasal airway, nighttime nasal airway, and olfactory function further improved slightly, whereas snoring improvement remained stable. Apnea decreased quite substantially during this period. This is probably attributable to a decrease in nasal edema at 6 months with further airway improvement. Mouth breathing returned somewhat at 6 months. These patients were habitual mouth breathers and apparently returned to mouth breathing even with an improved nasal airway.

At 6 months, static internal nasal valve areas increased, whereas external nasal valve dynamic areas decreased. A decrease in postoperative edema is again most likely the reason for both of these changes. Decreasing edema would further enlarge the internal valve area. Conversely, alar edema would have a stenting affect on the external nasal valve, imparting dynamic stability at this level. This added stability would be lost over time, as was seen in these patients.

Cosmetic changes were felt to be quite acceptable to the patients in exchange for the airway improvements they received. Theoretical concerns addressed in the pilot study, including tenting or loss of effectiveness, have not been seen in my patients. A single infection was easily treated.

The Monarch implant provides a simple, consistent, and apparently long-term option for correcting nasal valvular dysfunction. Additional long-term study and trials of alternative implantation techniques are currently under way.


AUTHOR INFORMATION

Correspondence: Dr Hurbis, South Coast Center for Cosmetic Surgery, 2695 N 17th St, Coos Bay, OR 97420 (churbis{at}charter.net).

Financial Disclosure: None reported.

Previous Presentation: This study was presented at the Sixth International Symposium for Facial Plastic Surgery; May 4, 2006; Las Vegas, Nevada.


REFERENCES

1. Meyer R, Javanovic B, Sabri D. All about nasal valve collapse. Aesthetic Plast Surg. 1996;20(2):141-151. ISI | PUBMED
2. Cole P, Roithmann R. The nasal valve and current technology. Am J Rhinol. 1996;10(1):23-31. FULL TEXT | ISI
3. Hurbis CG. An adjustable, butterfly-design, titanium-expanded polytetrafluoroethylene implant for nasal valve dysfunction. Arch Facial Plast Surg. 2006;8(2):98-104. FREE FULL TEXT






HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2008 American Medical Association. All Rights Reserved.