You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 5 No. 6, Nov-Dec 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Reconstructive Facial Surgery
 •Alert me on articles by topic

Comparison of Absorbable With Nonabsorbable Sutures in Closure of Facial Skin Wounds

G. Joseph Parell, MD; Gary D. Becker, MD

Arch Facial Plast Surg. 2003;5:488-490.

Background  There is long-standing disagreement among facial plastic surgeons as to the ideal suture material for closing skin wounds of the face. Many surgeons believe that nonabsorbable suture material is preferable, as it is easier to tie, is unlikely to break prematurely, and elicits a minimal inflammatory response. Others feel that these issues are of minor importance and prefer absorbable sutures because they do not have to be removed, thus saving the surgeon time and decreasing patient anxiety and discomfort.

Patients and Methods  Facial skin cancers were removed from 41 patients. The length of closure ranged from 3.5 to 12.0 cm. All wounds were closed with rotational advancement flaps. Deep tissues were closed with 4-0 poliglecaprone 25 (Monocryl; Ethicon Inc, Somerville, NJ). One half of each wound was randomly closed with 5-0 coated polypropylene (Prolene; Ethicon Inc), while the other half was closed with 5-0 coated irradiated polyglactin 910 (Vicryl Rapide; Ethicon Inc). No wound infections or premature rupture of sutures occurred. All patients were followed up for 6 months after surgery. The photographs of the results were reviewed, and no difference was noted in scar formation.

Conclusions  In adults with clean wounds of the face or neck, there is no difference in long-term cosmetic results of repairs with permanent or absorbable suture material. We prefer absorbable sutures, as they do not have to be removed, saving the surgeon time and lessening patient anxiety and discomfort.


From the Departments of Otolaryngology–Head and Neck Surgery, University of Florida Medical Center, Gainesville, Fla (Dr Parell), and Kaiser Permanente Medical Center, Panorama City, Calif (Dr Becker).



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

The Effect of a Hydrogen Peroxide Wound Care Regimen on Tensile Strength of Suture
Athre et al.
Arch Facial Plast Surg 2007;9:281-284.
ABSTRACT | FULL TEXT  