You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 10 No. 5, Sep-Oct 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Surgery
 •Biomaterials and Implants
 •Cosmetic Surgery/ Procedures
 •Alert me on articles by topic

Determination of Shear Strength of Periosteum Attached to Bone With BioGlue Surgical Adhesive

Douglas M. Sidle, MD; Corey S. Maas, MD

Arch Facial Plast Surg. 2008;10(5):316-320.

Objective  To determine the shear strength of BioGlue Surgical Adhesive (Cryolife Inc, Kennesaw, Georgia) for use in periosteal fixation in endoscopic browplasty.

Methods  In a controlled design, the shear strength of periosteal attachment to native bone and that of dissected periosteum affixed to bone with BioGlue surgical adhesive was physiologically determined. Twenty-one periosteum and bone samples were harvested from 3 human cadavers. These samples were tested for maximum shear strength using an Instron Model 5500 universal materials testing machine. Native samples consisted of periosteum still attached to the bone surface, while BioGlue samples consisted of dissected periosteum reattached to the bone surface using BioGlue surgical adhesive. The maximum shear strength attained for each sample was recorded and used to determine if native samples differed from those using BioGlue surgical adhesive.

Results  The mean (SD) maximum shear strength values obtained during testing were 57.8 (31.7) kPa and 45.9 (27.4) kPa (589.4 [323.3] gram force [gf]/cm2 and 468.0 [279.4] gf/cm2) for native (n = 8) and BioGlue (n = 9) samples, respectively. There was no statistical difference between the native and BioGlue samples (P > .05) using analysis of variance.

Conclusion  This study demonstrates that the adhesive properties of BioGlue are similar to the strength of attachment of native periosteum to bone and supports the use of BioGlue as an alternative method of fixation for use in endoscopic brow-lifting.


Author Affiliations: The Maas Clinic, San Francisco, California (Drs Sidle and Maas); Division of Facial Plastic Surgery, Department of Otolaryngology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois (Dr Sidle); and Division of Facial Plastic Surgery, Department of Otolaryngology, University of California, San Francisco (Dr Maas).