You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 10 No. 1, Jan-Feb 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Article
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Reconstructive Facial Surgery
 •Trauma/ Maxillofacial Surgery
 •Otolaryngology/ Head & Neck Surgery
 •Alert me on articles by topic

Clinical Analysis of Surgical Approaches for Orbital Floor Fractures

Jae Hwan Kwon, MD, PhD; Jeong Geun Kim, MD; Jung Hwan Moon, MD; Joong Hwan Cho, MD

Arch Facial Plast Surg. 2008;10(1):21-24.

Objective  To identify the optimal surgical method for managing blowout fractures of the inferior orbital wall by analyzing the location and type of fracture based on computed tomographic findings and medical records.

Methods  Medical records of 102 patients with pure inferior blowout fractures who were treated between June 1996 and December 2005 were reviewed regarding fracture type and location and surgical approach.

Results  Ocular symptoms persisted in 14 of the 102 cases after surgery, and revision procedures were performed in 11 of those cases. Cases with persistent symptoms were analyzed in terms of fracture location and type of surgery. For anterior orbital floor fractures, symptoms persisted in 2 of the 4 cases treated using a transantral approach, while no symptoms persisted in any of the 15 cases treated using a transorbital approach or in either of the 2 cases treated using a combined approach. For posterior orbital floor fractures, symptoms persisted in 2 of the 31 cases treated using a transantral approach, in 4 of the 6 cases treated using a transorbital approach, and in 1 of the 19 cases treated using a combined approach. For anteroposterior orbital floor fractures, symptoms persisted in 2 of the 5 cases treated using a transorbital approach and in 3 of the 20 cases treated using transantral and combined approaches.

Conclusion  Patients with large orbital floor fractures or posterior half fractures of the orbit should undergo surgery via a transantral or a combined approach, while patients with trapdoor fractures or anterior half fractures of the orbit should undergo surgery via a transorbital or a combined approach.


Author Affiliations: Department of Otorhinolaryngology–Head and Neck Surgery, Maryknoll Medical Center, Busan, Korea.